No.

Part name

15Replacement of temperature sensor for servicing only

Common service parts of sensor TO, TS, TE, TD

Procedure

1)Cut the sensor 100 mm longer than old one.

2)Cut the protective tube after pulling out it (200 mm).

3)Move the protective tube toward the thermal sensor side and tear the tip of lead wire in two then strip the covering part.

4)Pass the stripped part through the thermal constringent tube.

5)Cut the old sensor 100 mm length on the connector side, and recycle that connec- tor.

6)Tear the lead wire in two on the connector side and strip the covering part.

7)Twist the leads on the connector and sensor sides, and solder them.

8)Move the thermal constringent tubes toward the soldered parts and heat them with the dryer and constring them.

9)Wind the attached color tape round the both terminals of the protective tube when colored protective tube is used.

10)Fix the sensor again.

NOTE

Remarks

Thermal

Cutting here

Connector

 

 

100

 

 

sensor part

 

 

 

 

 

 

 

 

 

 

 

200Cutting here

 

 

15

Thermal

 

70

 

 

constringent tube

 

Cutting here

 

 

100

 

15

Soldered part

 

70

 

 

 

Dryer

Winding the color tape

These are parts for servicing sensors.

Please check that the accessories shown in the right table are packed.

1)Store the joint part of the sensor and the connector in the electric parts box.

2)Never joint them near the thermal sensor part.

Otherwise it would cause insulation inferiority because of dew drops.

3)When replacing the sensor using the colored protective tube, wind the color tape matching the color of that tube.

 

Parts name

Q'ty

Remarks

1

Sensor

1

Length : 3m

 

 

 

 

2

Sensor Spring (A)

1

For spare

3

Sensor Spring (B)

1

For spare

 

 

 

 

4

Thermal constringent tube

3

Including one spare

5

Color tape

1

9 colors

 

 

 

 

6

Terminal

3

 

 

 

 

 

16Cord heater assembly

(-ND model only)

1)Perform the procedures in above. (Do not perform the procedure in -6).)

2)Remove the cord clamp. (ST1Tø4 x 10L 1 pc.)

3)Remove the cord clamps (12 locations) fixing the cord heater assembly to the base plate.

4)Attach the new cord heater assembly to the base plate using the cord clamps supplied with the cord heater assembly. (Service code: 37557729)

Cord heater assembly

– 106 –

Page 106
Image 106
Toshiba RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-10SAVP-E service manual 106, Parts name Qty Remarks, Part name

RAS-10SAVP-E, RAS-B10SKVP-E, RAS-B13SKVP-E specifications

Toshiba has established itself as a leader in the HVAC market, known for its innovative technologies and reliable performance. Among its range of air conditioning units, the Toshiba RAS-B10SKVP-E, RAS-10SAVP-E, and RAS-B13SKVP-E models stand out for their efficiency and advanced features.

The Toshiba RAS-B10SKVP-E is designed for optimal cooling and heating efficiency, making it an ideal choice for small to medium-sized rooms. One of its main features is the Super Hi-M-PAM inverter technology, which enhances energy savings by continuously adjusting the compressor speed to match the cooling demand. This results in lower energy consumption while maintaining a stable temperature. Additionally, the unit boasts a 4-in-1 operation mode that allows users to select cooling, heating, dehumidification, or ventilating modes, ensuring maximum comfort at all times.

Similarly, the RAS-10SAVP-E model incorporates advanced features such as an eco-friendly refrigerant, R32, which has a lower Global Warming Potential (GWP) compared to traditional refrigerants. This model is equipped with a high-efficiency filter that captures dust and allergens, ensuring cleaner air quality. The sleek design allows for easy integration into various interior styles, while its quiet operation makes it a preferred choice for residential environments.

The RAS-B13SKVP-E model takes performance to the next level with a robust cooling capacity, designed for larger spaces. This model utilizes Toshiba's unique DC Hybrid Inverter technology, which not only enhances cooling efficiency but also facilitates faster temperature control. A notable characteristic of this unit is its wide-angle air distribution system, which allows for even airflow throughout the room, enhancing comfort.

In addition to these features, all three models are equipped with smart controls that enable users to operate their air conditioning systems remotely via mobile devices. This connectivity adds convenience and ensures that users can manage their indoor climate at their fingertips. They also come with user-friendly interfaces and programmable timers, allowing for personalized comfort settings.

In conclusion, the Toshiba RAS-B10SKVP-E, RAS-10SAVP-E, and RAS-B13SKVP-E air conditioning units combine energy efficiency, innovative technology, and user-friendly features to deliver exceptional indoor comfort. With their advanced technologies, these models are ideal choices for anyone seeking reliable and effective climate control solutions.