Toshiba RAS-10SAVP-E, RAS-B13SKVP-E, RAS-B10SKVP-E service manual Outdoor Unit, 98

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 98
Image 98
12-3. Outdoor Unit

12-3. Outdoor Unit

No. Part name

Procedure

Remarks

Common 1. Detachment

procedure

NOTE

Wear gloves for this job. Otherwise, you may injure your hands on the parts, etc.

1) Stop operation of the air conditioner, and turn off the main switch of the breaker for air conditioner.

2) Remove the valve cover. (ST1TØ4 × 8L 1 pc.)

• After removing screw, remove the valve cover pulling it downward.

3) Remove wiring cover (ST1TØ4 × 8L 2 pcs.), and then remove connecting cable.

4) Remove the upper cabinet. (ST1TØ4 × 8L 5 pcs.)

After removing screws, remove the upper cabinet pulling it upward.

2.Attachment

1) Attach the water-proof cover.

NOTE

The water-proof cover must be attached without fail in order to prevent rain water, etc. from entering inside the indoor unit.

2) Attach the upper cabinet. (ST1TØ4 × 8L 5 pcs.)

3) Perform cabling of connecting cable, and attach the wiring cover.

Place the wiring cover over the opening used to work on the con- necting wires of the side cabinet, and secure it using the two fixing screws (ST1TØ4 × 8L 2 pcs.).

At this point, the top cushion of the wiring cover must be on the inside of the opening.

4)Attach the valve cover. (ST1TØ4 × 8L 1 pc.)

Insert the upper part into the square hole of the side cabinet, set hook claws of the valve cover to square holes (at three positions) of the main unit, and attach it pushing upward.

– 98 –

Page 98
Image 98