6.Verify draft inducer motor operation.

Verify Ignition Module Safety Lockout Functions - cont.

6.Verify draft inducer motor operation.

A.Turn the oven on.

B.Visually inspect the convection motor for vibration while motor is running.

C.If vibration is present, motor operation did not pass test; contact your local authorized Hobart office for service.

D.If vibration is not present, motor operation passed.

Verify Operation of Steam System

1.Check steam system for proper operation.

A.Turn oven on and set to normal bake temperature.

B.Turn water supply on.

C.Allow system to cycle three times to stabilize temperature.

D.Set oven to call for steam.

E.Observe operation. If steam is not observed, contact your local authorized Hobart office for service.

After completion of the owner PM procedure, you will need to contact a qualified servicer for any needed repairs.