SECTION 3 − SPECIFICATIONS

3-1. Specifications

Rated Welding

Maximum

Maximum Open-

Amperes Input at

 

 

Weight

Overall

Rated Load Output

 

 

Circuit Voltage

KVA

KW

Output

Amperage

115 V, 60 Hz, Single-

W/ Gun

Dimensions

 

DC

 

 

 

 

 

 

Phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length: 16-7/8 in

90 A @ 19 Volts DC,

 

 

 

 

20

2.90

2.50

50 lb

(429 mm)

20% Duty Cycle

 

 

 

 

Width: 9-7/8 in

 

125

 

 

29

 

 

 

(22.7 kg)

63 A @ 21 Volts DC,

 

 

 

 

 

(251 mm)

 

 

 

 

15*

2.20*

1.77*

 

 

 

 

 

 

 

20% Duty Cycle*

 

 

 

 

 

 

 

 

Height: 12-1/8 in

 

 

 

 

 

 

 

 

 

(308 mm)

 

 

 

 

 

 

 

 

 

 

Wire Type

 

Flux Cored

 

 

Wire Feed Speed Range

 

 

 

 

 

 

 

 

 

 

 

.030 − .035 in

 

183 − 295 IPM (4.6 − 7.5 m/min) At No Load

And Dia

 

 

 

 

(0.8 − 0.9 mm)

 

112 − 236 IPM (2.8 − 6.0 m/min) Feeding Wire

 

 

 

 

 

 

 

 

 

 

* CSA Rating

3-2. Duty Cycle And Overheating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle is percentage of 10 min-

 

 

 

 

 

 

 

 

 

 

utes that unit can weld at rated load

 

 

 

 

 

 

 

 

 

 

without overheating.

 

200

 

 

 

 

 

 

 

 

If unit overheats, thermostat(s)

 

 

 

 

 

 

 

 

 

opens, output stops, and cooling

 

 

 

 

 

 

 

 

 

 

 

135

 

 

 

 

 

 

 

 

fan runs. Wait fifteen minutes for

 

 

 

 

 

 

 

 

 

unit to cool. Reduce amperage or

 

100

 

 

 

 

 

 

 

 

duty cycle before welding.

Amperes

 

 

 

 

 

 

 

 

Y Exceeding duty cycle can

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

damage unit or gun and void

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

warranty.

40

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

10

2

4

6

8

10

 

40

60

100

 

1

20

 

 

 

 

Duty Cycle %

 

 

 

 

 

 

 

 

20% duty cycle at 90 amps

 

 

 

 

 

 

2 Minutes Welding

 

 

8 Minutes Resting

 

 

Overheating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

A or V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minutes

 

 

Reduce Duty Cycle

 

 

 

 

 

 

 

 

 

duty1 4/95 − 210 517-A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OM-923 Page 9

Page 13
Image 13