NI-3000 Specifications (Cont.)

Introduction

NI-3000 Specifications (Cont.)

Dimensions (HWD):

• 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)

 

• 2 RU (rack unit) high

 

 

Power requirements:

• 900 mA @ 12 VDC

 

 

Memory:

• 32 MB SDRAM

 

• 1 MB of Non-volatile Flash

 

 

Compact Flash:

• 32 MB Card (upgradeable). Refer to the Optional Accessories section on

 

page 10 for more information.

 

 

Weight:

• 4.55 lbs (2.06 kg)

 

 

Enclosure:

• Metal with black matte finish

 

 

Front Panel Components:

 

LINK/ACT

• Green LED lights when the Ethernet cable is connected and an active link

 

is established. This LED also blinks when receiving Ethernet data packets.

 

 

Status

• Green LED lights to indicate that the system is programmed and

 

communicating properly.

 

 

Output

• Red LED lights when the Controller transmits data, sets channels On/Off,

 

sends data strings, etc.

 

 

Input

• Yellow LED lights when the Controller receives data from button pushes,

 

strings, commands, channel levels, etc.

 

 

RS-232/422/485 LEDs

Seven sets of red and yellow LEDs light to indicate the rear DB9 Ports 1-7

 

are transmitting or receiving RS-232, 422, or 485 data:

 

- TX LEDs (red) light when transmitting data

 

- RX LEDs (yellow) light when receiving data

 

- LED activity reflects transmission and reception activity

 

 

Relay LEDs

Eight red LEDs light to indicate the rear relay channels 1-8 are active

 

(closed)

 

• These LEDs reflect the state of the relay on Port 8

 

• If the relay is engaged = LED On and if the relay is Off = LED Off

 

 

IR/Serial LEDs

Eight red LEDs light to indicate the rear IR/Serial channels 1-8 are

 

transmitting control data on Ports 9-16

 

• LED indictor for each IR port remains lit for the length of time that IR/Serial

 

data is being generated

 

 

I/O LEDs

Eight yellow LEDs light when the rear I/O channels 1-8 are active

 

• LED indicator for each I/O port reflects the state of that particular port

 

 

Rack-mount brackets

• Provide an installation option for the Integrated Controller to be mounted

 

into an equipment rack.

 

 