AMX NI-3000, NI-2000 NI-4000 Specifications Cont, Introduction, Rear Panel Components

Models: NI-2000 NI-4000 NI-3000

1 134
Download 134 pages 57.78 Kb
Page 18
Image 18
NI-4000 Specifications (Cont.)

Introduction

NI-4000 Specifications (Cont.)

Relay LEDs

Eight red LEDs light to indicate the rear relay channels 1-8 are active

 

(closed)

 

• These LEDs reflect the state of the relay on Port 8

 

• If the relay is engaged = LED On and if the relay is Off = LED Off

 

 

IR/Serial LEDs

Eight red LEDs light to indicate the rear IR/Serial channels 1-8 are

 

transmitting control data on Ports 9-16

 

• LED indictor for each IR port remains lit for the length of time that IR/Serial

 

data is being generated

 

 

I/O LEDs

Eight yellow LEDs light when the rear I/O channels 1-8 are active

 

• LED indicator for each I/O port reflects the state of that particular port

 

 

NetLinx Control

Accepts up to 4 compatible NetLinx Control Cards:

Card slots 1- 4

NXC-COM2 Dual COM Port Control Card (FG2022)

 

 

NXC-I/O10 Input/Output Control Card (FG2021)

 

NXC-IRS4 4-Port IR/S Control Card (FG2023)

 

NXC-REL10 Relay Control Card (FG2020)

 

NXC-VAI4 Analog Voltage Control Card (FG 2025)

 

NXC-VOL4 Volume Control Card (FG2024)

 

 

Rack-mount brackets

• Provide an installation option for the Integrated Controller to be mounted

 

into an equipment rack.

 

 

Rear Panel Components:

 

RS-232/422/485 (Ports 1 -7)

Seven RS-232/422/485 control ports using DB9 (male) connectors with

 

XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to

 

send), and 300-115,200 baud.

 

• Channel range = 1-255

 

• Channels 1-254 provide feedback

 

• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a

 

'CTSPSH' command was sent to the port

 

• Output data format for each port is selected via software

 

• Seven DB9 connectors provide RS-232/422/485 termination

 

 

ICSNet

Two RJ-45 connectors for ICSNet interface

 

 

ICSHub Out

Single RJ-45 connector provides data to another Hub connected to the

 

Controller

 

 

Relay (Port 8)

Eight-channel single-pole single throw relay ports

 

• Each relay is independently controlled.

 

• Supports up to 8 independent external relay devices

 

• Channel range = 1-8

 

• Each relay can switch up to 24 VDC or 28 VAC @ 1 A

 

• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay

 

termination

 

 

 

12

NetLinx Integrated Controllers

 

 

 

Page 18
Image 18
AMX NI-3000, NI-2000 instruction manual NI-4000 Specifications Cont, Introduction, Rear Panel Components