Configuration and Firmware Update

If the NI Integrated Controller firmware version is not version 1 - build 121 or higher (ex: v1.XX.121), download the latest NI Integrated Controller firmware file from www.amx.com > Tech Center > Downloadable Files > Firmware Files >

NI Series. Then Download the 2105 NI_X000 KIT file to your Controller.

2.Verify you have downloaded the latest NetLinx Integrated Controller (KIT) file to a known location.

3.Select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (FIG. 33). Verify the target’s Device and System numbers matches the value listed within the System folder in the Workspace window.

Selected Integrated Controller

 

Description field for selected KIT file

Firmware file (NI_X000)

 

 

 

 

Firmware download status

System Number and Device Number must match the System and Device values listed in the Workspace window

FIG. 33 Select NI firmware file for download page (via IP)

4.Select the Integrated Controller’s KIT file from the Files section (FIG. 33).

5.Enter the System number associated with the desired Master (listed in the Workspace window).

6.Enter the Device number of the target NetLinx Integrated Controller.

7.Click the Reboot Device checkbox to reboot the on-board Master after the firmware update to the Integrated Controller is complete.

8.Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (FIG. 33).

9.Click Close once the download process is complete.

The OUTPUT and INPUT LEDs alternately blink to indicate the Master is incorporating the new firmware. Allow the Master 20 - 30 seconds to reboot and incorporate the new firmware.

 

50

NetLinx Integrated Controllers

 

 

 

Page 56
Image 56
AMX NI-2000, NI-3000, NI-4000 Selected Integrated Controller, Firmware file NIX000 Firmware download status