Programming

Programming

Programming

This section describes the Send_Commands, Send_Strings, and Channel commands you can use to program the Integrated Controller. The examples in this section require a declaration in the DEFINE_DEVICE section of your program to work correctly. Refer to the NetLinx Programming Language instruction manual for specifics about declarations and DEFINE_DEVICE information.

Converting Axcess Code to NetLinx Code

In order to compile your existing Axcess code to NetLinx code, minor modifications will be required. These modifications include identifier names that conflict with NetLinx identifiers, warning on variable type conversions, and stricter syntax rules.

For more information on NetLinx standards and conversion recommendations, go to www.amx.com and click on Dealers > Tech Center > Tech Notes. You can either search for the documents (such as NetLinx Programming Standards and Converting Axcess Code to NetLinx Code) or Tech Notes (TN numbers: 186, 249, 261, and 310).

Refer to the NetLinx Programming Instruction Manual for more detailed information on the differences between the two codes and how they can be re-written. The section is called Converting Axcess Code to NetLinx Code.

Using the ID Button

The ID Button on the rear panel of the Integrated Controller is used in conjunction with the NetLinx Studio 2.2 software program to allow you to assign new Device and System numbers for the Integrated Controller.

1.Using NetLinx Studio 2.2, place the system in Identity (ID) Mode. ID Mode means the entire system is put on hold while it waits for an event from any NetLinx device in the named system (for example, pushing the ID button on the Integrated Controller). The device that generates the first event is the identified device.

2.Press the ID Mode button to generate an event from the Integrated Controller and assign new device and system numbers in NetLinx Studio.

Only the Device number can be changed on the Controllers using the ID button.

Port and System can not be defined.

Device:Port:System (D:P:S)

A device is any hardware component that can be connected to an AXlink or ICSNet bus. Each device must be assigned a unique number to locate that device on the bus. The NetLinx programming language allows numbers in the range 1-32,767 for ICSNet (255 for AXlink).

NetLinx requires a Device:Port:System (D:P:S) specification. This D:P:S triplet can be expressed as a series of constants, variables separated by colons, or a DEV structure.

NetLinx Integrated Controllers

109

 

 

 

 

Page 115
Image 115
AMX NI-4000, NI-3000 Programming, Converting Axcess Code to NetLinx Code, Using the ID Button, DevicePortSystem DPS