AMX NI-2000, NI-3000, NI-4000 Ethernet 10/100 Base-T RJ-45 Connections/Wiring, ICSHub OUT port

Models: NI-2000 NI-4000 NI-3000

1 134
Download 134 pages 57.78 Kb
Page 29
Image 29
ICSHub OUT port

Connections and Wiring

The FIG. 11 illustrates the relative location of the ICSNet and ICSHub Out connectors on the rear panel.

ICSHub OUT Pinouts and Signals Ports

PORT 1

ICSNet

ICSNet ICSHub Out

FIG. 11 Location of ICSNet and ICSHub Out connectors

Unlike the ICSNet ports, the ICSHub connections require a specific polarity. The IN/OUT configuration, on the hub ports, was implemented to use the same cables as ICSNet, but these ports need TX and RX crossed. You must connect an OUT to an IN, or an IN to an OUT port.

This is done simply to keep the polarity straight. The Hub bus is still a bus. All Hub connections are bi-directional.

ICSHub OUT port

The following table describes the pinout/signal information for the ICSHub OUT port located on the rear panel of the Integrated Controller (as shown in FIG. 11).

ICSHub OUT Pinouts and Signals

Pin

Signal

Color

 

 

 

1

RX +

orange-white

 

 

 

2

RX -

orange

 

 

 

3

------

------

 

 

 

4

------

------

 

 

 

5

------

------

 

 

 

6

------

------

 

 

 

7

TX +

brown-white

 

 

 

8

TX -

brown

 

 

 

Ethernet 10/100 Base-T RJ-45 Connections/Wiring

The following table lists the pinouts and signals associated to the Ethernet connector. FIG. 12 describes the RJ-45 pinouts, signals, and pairing for the Ethernet 10/100 Base-T RJ-45 connector and cable.

Ethernet RJ-45 Pinouts and Signals

Pin

Signals

Connections

 

Pairing

Color

 

 

 

 

 

 

 

1

TX +

1 ---------

1

1

--------- 2

Orange-White

 

 

 

 

 

 

 

2

TX -

2 ---------

2

 

 

Orange

 

 

 

 

 

 

 

3

RX +

3 ---------

3

3

--------- 6

Green-White

 

 

 

 

 

 

 

4

no connection

4 ---------

4

 

 

Blue

 

 

 

 

 

 

 

5

no connection

5 ---------

5

 

 

Blue-White

 

 

 

 

 

 

 

6

RX -

6 ---------

6

 

 

Green

 

 

 

 

 

 

 

7

no connection

7 ---------

7

 

 

Brown-White

 

 

 

 

 

 

 

8

no connection

8 ---------

8

 

 

Brown

 

 

 

 

 

 

 

FIG. 12 diagrams the RJ-45 cable and connectors.

NetLinx Integrated Controllers

23

 

 

 

 

Page 29
Image 29
AMX NI-2000, NI-3000 Ethernet 10/100 Base-T RJ-45 Connections/Wiring, ICSHub OUT port, ICSHub OUT Pinouts and Signals