Configuration and Firmware Update

Recommended NetLinx Device numbers

• 1 - 255

• Axcess Devices use Axcess standards

• 301 - 3072

• NetLinx CardFrames start at frame number 25 - (frame# * 12) + Card #

• 5001 - 5999

• ICSNet NetLinx devices: NXI, NXM-COM2, NXM-IRS4, etc.

• 6001 - 6999

• ICSNet Landmark devices: PLH-VS8, PLH-AS16, PLB-AS16

• 7001 - 7999

• InConcert Devices

• 8001 - 8999

• PCLink Device: PCLink devices are PC programs

• 10000 - 31999

• ICSNet Panels: DMS, IMS, and future panels

• 33001 - 36863

• Virtual devices: these start at 33001

• 32001 - 32767

• Dynamic devices: the actual range used by Master

• 32768 - 36863

• Virtual devices: the actual range used by Master

Resetting the Factory Default System and Device Values

1.Access the Device Addressing dialog box (FIG. 25 on page 40) by either one of these two methods:

Right-click on any system device listed in the Workspace and select Device Addressing.

Select Diagnostics > Device Addressing from the Main menu.

2.Click the Set Device/System to Factory Default button. This resets both the system value and device addresses (for definable devices) to their factory default settings. The system information (in the OnLine Tree tab of the Workspace window) refreshes and then displays the new information.

By setting the system to its default value (#1), Modero panels that were set to connect to the Master on another System value will not appear in the OnLine Tree tab of the Workspace window.

For example: A Modero touch panel was previously set to System #2. The system is then reset to its default setting of System #1 and then refreshed from within the Workspace window. The panel will not reappear until the system is changed (from within the System Connection page on the Modero) to match the new value and both the Master and panel are rebooted.

3.Click Done to close the Device Addressing dialog.

4.Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until the STATUS LED is the only LED to blink.

5.Press Done once the Master Reboot Status field reads Reboot of System Complete.

6.Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one (1).

7.Right-click the associated System number and select Refresh Whole Network to refresh of all project systems, establish a new connection to all Masters, and refresh the System list with devices on that system.

8.Use Ctrl+S to save your existing NetLinx Project with the new changes.

NetLinx Integrated Controllers

41

 

 

 

 

Page 47
Image 47
AMX NI-2000, NI-3000, NI-4000 Resetting the Factory Default System and Device Values, Recommended NetLinx Device numbers