Installation and Upgrading

Installation and Upgrading

Installation and Upgrading

Installing NetLinx Control Cards (NI-4000 Only)

NetLinx Cards can be installed into the front card slots. The cards mount horizontally through the card slot openings on the front of the enclosure. To install a NetLinx Card:

1.Discharge the static electricity from your body, by touching a grounded object.

2.Remove the three screws by turning them in a counter-clockwise direction and then remove the faceplate (FIG. 18).

Thumbscrews

NXC Card Slot faceplate

FIG. 18 NI-4000 front faceplate

3.Align the edges of the card with the internal guide slots and gently slide the card all the way into the slot (FIG. 19).

Card slots

Sample NXC cards

Internal Guide slots

FIG. 19 Sample NXC cards inserted into an NI-4000 unit

4.Carefully apply a small amount of force to insert the cards into their respective connectors. If the cards have LEDs on them, those LEDs will initiate a lighting sequence to indicate they are receiving power and are communicating with the Controller.

5.Re-align the faceplate and secure it to the chassis by inserting the three screws by turning them in a clockwise direction and securing the front plate to the Integrated Controller.

6.Install all rear connectors and apply power.

NetLinx Integrated Controllers

29

 

 

 

 