AMX NI-3000, NI-4000, NI-2000 instruction manual Upgrading the Control Card Firmware via an IP

Models: NI-2000 NI-4000 NI-3000

1 134
Download 134 pages 57.78 Kb
Page 57
Image 57
Upgrading the Control Card Firmware via an IP

Configuration and Firmware Update

10.Right-click the System number and select Refresh System. This establishes a new connection to the System and populates the list with the current devices (and their firmware versions) on your system.

Upgrading the Control Card Firmware via an IP

Before beginning with this section, verify the Integrated Controller’s on-board Master has been updated with the latest firmware and that the NetLinx cards are securely inserted into the NI-4000 (refer to the Installing NetLinx Control Cards (NI-4000 Only) section on page 29).

1.Repeat the communication setup procedures outlined within the Upgrading the NI Controller Firmware via an IP section on page 48.

2.Click on the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one (1).

3.Right-click on the Empty Device Tree/System entry and select Refresh System to establish a new connection to the System’s Master and refresh the list with online system devices.

4.After the Communication Verification dialog window verifies active communication between the PC and the Master, verify the NetLinx Control Cards appear in the OnLine Tree tab of the Workspace window.

If the control card firmware is not up to date; download the latest firmware file from www.amx.com > Tech Center > Downloadable Files > Firmware Files > NXC-XXX.

In this example, the NXC-VOL card contains out-of-date firmware and requires build 1.00.09.

5.Verify you have downloaded the latest NetLinx Control Card firmware (KIT) file to a known location.

6.Select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (FIG. 34). Verify the target’s Device and System numbers matches the value listed within the System folder in the Workspace window.

7.Select the Control Card’s KIT file from the Files section (FIG. 34).

8.Enter the System number associated with the desired Master (listed in the Workspace window).

9.Enter the Device number of the target NetLinx Control Card.

10.Click the Reboot Device checkbox to reboot the on-board Master after the firmware update to the NetLinx Control Card is complete.

11.Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (FIG. 33).

12.Click Close once the download process is complete.

NetLinx Integrated Controllers

51

 

 

 

 

Page 57
Image 57
AMX NI-3000, NI-4000, NI-2000 instruction manual Upgrading the Control Card Firmware via an IP