PROGRAMMING

Temperature, time and other parameters must be set before operating. Follow the Program Guide to configure the fryer to your particular operation.

Programming Guide

Press P to enter into the program mode, then follow the steps under each parameter to enter the

desired information. To exit the parameter and save changes, press P . To exit the program

completely, press P again.

PARAMETER

 

 

STEPS

LEFT DISPLAY

RIGHT DISPLAY

 

Press

0

 

SELECT

OPTIONS

 

 

 

 

 

Fahrenheit or

Press

1

 

DEGREES F or C

F or C

 

 

 

 

Celsius

 

 

 

 

 

 

Press

 

to select Fahrenheit or Celsius.

DEGREES F or C

F or C

 

Press

P

when complete.

PROGRAM

 

 

Press

0

 

SELECT

OPTIONS

No Password

Press

2

 

SET PASS

NEW PASS

 

 

 

 

Required

 

 

 

 

 

 

Press

 

to select NO PASS.

NO PASS

NEW PASS

 

Press

P

when complete.

PROGRAM

 

 

Press

0

 

SELECT

OPTIONS

 

 

 

 

 

 

Press

2

 

SET PASS

NEW PASS

 

 

 

 

 

Password

 

 

 

 

 

Required

Press

 

to select PASS REQ.

PASS REQ

NEW PASS

 

 

 

Press

P

and enter numeric code.

CODE XXXX

NEW PASS

 

Press

P

when complete.

PROGRAM

 

 

Press

0

 

SELECT OPTIONS

OPTIONS

Beeper

Press

3

 

VOLUME #

BEEPER

 

 

 

 

Volume

 

 

 

 

 

 

Press

 

to select volume.

1, 2 or 3

BEEPER

 

Press

P

when complete.

PROGRAM

 

– 22 –

Page 22