ALARMS AND ERROR MESSAGES (HGD and HGC Series)

ALARMS AND ERROR MESSAGES (HGD and HGC Series)

Pilot Out - If the pilot is out, the control displays the following message:

HGD Series -

FIrE OUt

HGC Series -

PILOT OUT

If no action is taken after 90 seconds an alarm sounds continuously, the heat demand is disabled and any running cooking cycles are cancelled. The control displays the following message:

HGD Series - Ign LoC

HGC Series - IGNITION LOCKOUT

The fryer must be turned off, then back on before the pilot can be relit and normal fryer functions resumed. See pages 14 and/or 15 under Startup for lighting instructions pertaining to your particular model.

Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

HGD Series -

Prob

HGC Series -

OPEN PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off then back on. If the problem persists, call service.

Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

HGD Series - Hi

HGC Series - SHORTED PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off then back on. If the problem persists, call service.

Hi Temperature - If the actual temperature is greater or equal to 415°F (212°C), the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

HGD Series - Hi

HGC Series - SHORTED PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off then back on. Normal fryer operations resumes when temperature drops below 415°F (212°C). If the problem persists, call service.

FORM 34773 (June 2002)

– 36 –