ALARMS AND ERROR MESSAGES (HGD and HGC Series)
Pilot Out - If the pilot is out, the control displays the following message:
HGD Series - | FIrE OUt |
HGC Series - | PILOT OUT |
If no action is taken after 90 seconds an alarm sounds continuously, the heat demand is disabled and any running cooking cycles are cancelled. The control displays the following message:
HGD Series - Ign LoC
HGC Series - IGNITION LOCKOUT
The fryer must be turned off, then back on before the pilot can be relit and normal fryer functions resumed. See pages 14 and/or 15 under Startup for lighting instructions pertaining to your particular model.
Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - | Prob |
HGC Series - | OPEN PROBE |
The alarm sounds continuously until the fault clears or the fryer is turned off then back on. If the problem persists, call service.
Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off then back on. If the problem persists, call service.
Hi Temperature - If the actual temperature is greater or equal to 415°F (212°C), the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off then back on. Normal fryer operations resumes when temperature drops below 415°F (212°C). If the problem persists, call service.