TROUBLESHOOTING
SYMPTOM |
| POSSIBLE CAUSE |
|
| POSSIBLE REMEDY |
Booster pump doesn't | 1. | Storage tank ball valve closed. | 1. | Open ball valve. | |
operate. | 2. | No power at electrical outlet. | 2. | Restore power at outlet. | |
| 3. | Transformer malfunction. |
|
|
|
| 4. | Booster pump malfunction. | Contact your local Hobart Service office. | ||
| 5. | High pressure switch malfunction. |
|
|
|
|
|
| |||
Booster pump runs | 1. Sampling shutoff valve or | 1. Close valve(s). | |||
continuously. |
| equipment valve malfunction. |
|
|
|
| 2. | Check Valve on product water |
|
|
|
|
| outlet of RO membrane housing | |||
|
| malfunction. | |||
|
|
|
|
| |
| 3. | High pressure switch malfunction. |
|
|
|
|
|
|
|
| |
No RO product water | 1. | No power at electrical outlet. | 1. | Restore power at outlet. | |
output to equipment. | 2. | Inlet shutoff or output valve(s) |
|
|
|
|
| closed. |
|
|
|
| 3. | Clogged | Contact your local Hobart Service office. | ||
| 4. | Transformer malfunction. |
|
|
|
| 5. | Electronic shutoff valve |
|
|
|
|
| malfunction. |
|
|
|
Low RO product water | 1. | Clogged filter(s). | 1. | Replace filter(s). | |
output to equipment. | 2. | Low inlet water pressure. |
|
|
|
| 3. | Mineral scaling on RO |
|
|
|
|
| membrane. | Contact your local Hobart Service office. | ||
| 4. | Permeate pump malfunction. |
|
|
|
Low RO product water | 1. Storage tank air pressure not |
|
|
| |
yield. (Draw down less |
| correct. |
|
|
|
than 13 gallon when | 2. Low inlet water pressure. |
|
|
| |
full) | 3. | Clogged filter(s). | Contact your local Hobart Service office. | ||
| |||||
| 4. | Mineral scaling on RO |
|
|
|
|
| membrane. |
|
|
|
| 5. | Permeate pump malfunction. |
|
|
|
|
|
|
|
| |
Equipment water level | 1. | Product water mineral content too | 1. | Contact your local Hobart Service office. | |
probes not operating |
| low. |
|
|
|
properly. | 2. | Bypass valve set incorrectly. | 2. | Ensure bypass valve is closed. | |
| 3. | Cooking equipment probe | 3. Check cooking equipment instruction | ||
|
| malfunction. |
| manual for possible solution. | |
|
|
|
|
|
|
Metallic plumbing on | 1. | Product water mineral content too |
|
|
|
equipment shows |
| low. | 1. | Contact your local Hobart Service office. | |
signs of corrosion. |
|
|
|
|
|
Brine water flows | 1. Check Valve on product water |
|
|
| |
continuously through |
| outlet of RO membrane housing | |||
drain. (Booster pump |
| malfunction. | |||
|
|
|
| ||
is not operating.) | 2. | Permeate pump malfunction. |
|
|
|