Installation, Operation and Care of
RO-150 Reverse Osmosis System
SAVE THESE INSTRUCTIONS
GENERAL
The Hobart
NOTE: The standard storage tank size is 20 gallon. Other sizes of storage tanks are available (up to 80 gallon).
NOTE: The
Filter cartridge replacement is recommended at least every 4 - 6 months for moderate to low usage and 90 days for high usage. The RO membrane should be replaced annually or when the removal of Total Dissolved Solids - TDS becomes less than 80% efficient (determined by comparison testing of water supply and product water).
UNPACKING
This water filter system was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the water filter system is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
INCLUDED IN
•Reverse osmosis filtration system assembly with supplied filters, cartridges and 24VAC transformer.
•20 Gallon storage tank (13 gallon capacity)*.
•3/8" Push on ball valve
•3/8" to 1/4" Push on tee
•1/4" Ball valve
•10' - 3/8" LLDPE John Guest tubing
•10' - 1/4" LLDPE John Guest tubing
•3/8" Plastic ferrules and stainless steel stiffening inserts
•Filter wrench
*The
REQUIRED TOOLS
•Spirit Level
•PVC pipe cutter, razor blade tubing cutter or sharp razor knife
•Electric drill
•Marker
•Air pressure gauge capable of measuring
REQUIRED HARDWARE
•Connection fitting to water supply with 3/8" compression fitting
•Connection fitting to equipment with 3/8" compression fitting
•Teflon tape
•Two 3/16" diameter mounting screws at least 1- 1/4" in length.
•Appropriate wall anchor hardware for 3/16" screws