INSTALLATION

MOUNTING LOCATION REQUIREMENTS CAUTION: Do not mount to equipment.

1.The filter system must be mounted on a sturdy support structure or wall and must be level.

2.Allow a minimum of ten inches clearance around the left and right sides and 14 inches clearance from the bottom of the system for routine maintenance and servicing.

3.Locate the RO filter system and storage tank near the equipment it services.

DIMENSIONS OF SYSTEM SHOWN

NOTE: The shorter the distance between the RO filter system and the equipment, the lower the water delivery line pressure drop.

4.Ensure there is an open drain nearby to drain waste water produced by the RO system. Most commonly this is the same drain used by the equipment the RO filter system is servicing.

5.Make sure 120V electrical service is within six feet of the RO mounting location.

6.Do not install the RO filter system where it will be exposed to hot air or steam exhaust.

7.The filter system must be protected against freezing. Failure to do so could result in breakage of the filter housing and water leakage.

MOUNTING THE RO-150

NOTE: The Hobart RO-150 can be mounted on a wall or other stable surface that will support its wet weight of 30 lbs. When mounted to a wall, the mounting hardware used must be able support its full weight and withstand the additional forces applied during pre-filter replacement.

Wall Mounting

1.Remove the pre-filters from the filtration system.

A.Lift the pre-filter head assembly to the desired location.

B.Level pre-filter head against mounting structure.

C.Mark the two mounting hole locations.

2.Drill mounting holes to the required diameter (depends on wall anchors being used).

3.Install two 3/16" mounting screws at least 1-1/4" in length in the marked locations using the appropriate wall anchors. Screw in the mounting screws leaving a 1/8"-1/4" gap. Lift the pre-filter head assembly and install over mounting screws. Slide pre-filter head assembly into place then securely tighten the mounting screws.

CAUTION: Do not plug in the transformer at this time.

4.Place the transformer in the space provided to the right of the permeate pump.

5.Connect the transformer 24V output to the wiring harness.

A.Route transformer output wiring under right side of bracket and connect to plug located on the left side of filter system near high pressure switch.

6.Insert filter cartridge into the pre-filter housings.

A.Verify that the filter cartridge being installed matches the labeling on the bracket.

B.For each pre-filter, ensure the O-ring is in place on pre-filter housing and hand tighten filter housing onto the pre-filter head.

-4-