WATER SUPPLY REQUIREMENTS
NOTE: Install the
NOTE: The following are recommended inlet water supply parameters. Exceeding these parameters may decrease system performance or result in more frequent filter changes. Most municipal water supplies will meet these conditions with the exception of water hardness. In cases where water hardness exceeds the maximum recommended levels, life of the RO membrane may be shortened. Proper system performance checks will determine if the membrane needs replacement.
WATER PARAMETERS
Inlet Water Supply TDS | < 2,000 ppm |
Hardness | < 10 grains (171 ppm) |
Iron | < 0.2 ppm |
Manganese | < 0.05 ppm |
Turbidity | < 5 NTU |
pH | 5 |
Free Chlorine | < 2 ppm |
Hydrogen Sulfide | None Allowable |
Feed Water Temperature | 40 - 100° F |
Feed Water Pressure | 20 - 125 psi |
PLUMBING CONNECTIONS
WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES.