SECTION 5 − MAINTENANCE AND TROUBLESHOOTING

5-1. Routine Maintenance

!

Disconnect power

. Maintain more often

 

before maintaining.

during severe conditions.

n = Check

Z = Change

~ = Clean

l = Replace

Reference

* To be done by Factory Authorized Service Agent

 

 

Every

 

 

 

 

3

 

 

 

 

Months

 

 

 

 

l Damaged Or Unreadable l Cracked Parts

n l Cables

n ~ Tighten Weld

Labels

 

 

 

Terminal

OR

 

 

 

 

Every

 

 

 

 

6

 

 

 

 

Months ~ Inside Unit

n Remove drive roll

 

 

 

and apply light coat

 

 

 

of oil or grease to

 

 

 

drive motor shaft

 

 

5-2. Supplementary Protectors

! Turn Off unit.

2

1

1Supplementary Protector CB1 CB1 protects main circuit board PC1.

2Supplementary Protector CB2

CB2 protects the drive motor circuit from overload. If drive motor shorts or fails: check gun liner blockage or kinks, check for jammed wire or bind- ing drive rolls.

Correct problem. Press button to reset supplementary protector.

SPOOL GUN

CB2

MIG GUN

CB1

 

Ref. 242 160-A