6-3. Status/Trouble Lights

. Difficulty establishing a pilot arc may indicate consumables need to be cleaned or replaced.

 

 

 

V POWER

 

 

 

 

PRESSURE

 

 

 

 

CUP

 

 

 

 

TEMP

 

 

 

 

 

 

 

 

 

Light

Condition

 

Status/Possible Cause

 

 

 

 

Power

On

 

Input power is okay.

 

 

 

 

Pressure/Cup/Temp

Off

 

When Power light is on, system is normal if these lights

 

 

 

 

are off.

 

 

 

 

 

 

 

 

 

Power

Flashing rate is steady for 15 seconds or until torch trigger

 

Input power below 156 volts AC, but has returned to

is pressed again, whichever comes first.

 

normal.

 

 

 

 

 

 

Power

Repetitive flashing rate of two quick cycles, then a one

 

Input power is below 156 volts AC.

second pause.

 

 

 

 

 

 

 

 

 

Pressure

On

 

No or low [below 40 psi (276 kPa)] input pressure.

 

 

 

 

 

Flashing rate is steady for 15 seconds or until torch trigger

 

Regulated pressure in the unit is low. Check torch for

Pressure

is pressed again, whichever comes first.

 

leaks. Check input pressure to unit is between 90 to 120

 

 

 

 

 

psi (621 to 827 kPa).

 

 

 

 

Pressure

Repetitive flashing rate of two quick cycles, then a one

 

Regulated pressure in the unit is high. Check input pressure

second pause for a 15 second period.

 

to unit is between 90 to 120 psi (621 to 827 kPa).

 

 

 

 

 

 

Cup

On

 

Torch cup is loose or off. Once cup is tightened, unit

 

 

 

 

power must be cycled off and back on again.

 

 

 

 

 

 

 

 

 

Cup

Flashing rate is steady for 15 seconds or until torch trigger

 

No arc was established. Check consumables or torch.

is pressed again, whichever comes first.

 

 

 

 

 

 

 

 

 

 

Repetitive flashing rate of two quick cycles, then a one

 

No pilot arc established possibly due to a loss of current.

Cup

second pause for a 15 second period or until torch trigger

 

Check consumables.

 

is pressed again, whichever comes first.

 

 

 

 

 

 

 

Repetitive flashing rate of three quick cycles, then a one

 

Consumables in torch failed to separate during pilot arc

Cup

second pause for a 15 second period or until torch trigger

 

possibly due to being stuck. Check consumables.

 

is pressed again, whichever comes first.

 

 

 

 

 

 

Temperature

On

 

Power source overheated (see Section 4-2). Stop cutting

 

 

 

 

and allow unit to cool down.

 

 

 

 

 

 

 

 

 

Temperature

On (indefinitely)

 

Power source temperature sensors may have failed or

 

 

 

 

ambient temperature is below -22°F (-30°C).

 

 

 

 

 

 

 

 

 

 

Flashing rate is steady (indefinitely).

 

Power source temperature sensor provided inaccurate

Temperature

 

 

 

 

readings, but returned to normal. Unit power must be

 

 

 

 

 

cycled off and back on again.

 

 

 

 

 

 

For system troubleshooting see Section 6-7 and Section 6-8.

6-4. Checking Shield Cup Shutdown System

. Power must be reset whenever the cup

shutdown system is activated. Always turn Off power when changing or checking consumables. Do NOT overtighten torch shield cup. Gently finger tighten cup onto torch.

1

1Torch Shield Cup

Turn Power On and loosen shield cup. If shutdown system works properly, Cup light comes on. If not, immediately turn Off power and have Factory Authorized Service Agent check unit.

If system works properly, retighten cup and reset power.

Ref. 801 300-A