.A complete Parts List is available at www.MillerWelds.com

6-6. Torch And Work Cable Connections

! Turn power Off, and disconnect input power plug from receptacle. Check to see that all diagnostic LED’s have stopped flashing before removing wrapper from unit.

67

2

5

7 5 6 9

32

4

8

Tools Needed:

3/8 in.

If torch or work cable needs to be removed or replaced, proceed as follows:

1Power Source Remove wrapper from unit.

Torch Connections

Remove existing torch cable from unit.

2 Strain Relief

3 Torch Cable

1 Insert strain relief on end of cable through front panel opening. Slide strain relief nut onto torch cable, but

do not tighten.

4Air Line Connector

Insert air line into solenoid fitting.

5Plug PLG4/Receptacle RC4

Connect PLG4 from torch to receptacle RC4 on end of wiring harness connected to circuit board PC1.

Route torch white and red leads and work black lead through sleeving the same way as the unit was originally.

6Ring Terminal And TORCH WHITE Terminal

Connect ring terminal on end of torch white lead to TORCH WHITE terminal.

7Ring Terminal And TORCH RED Terminal

Connect ring terminal on end of torch red lead to TORCH RED terminal.

Tighten strain relief screw.

Work Cable Connections

Remove existing work cable from unit.

8Strain Relief

Loosen strain relief screw.

.Be sure to allow some work cable slack inside the unit.

Insert strain relief on end of cable through front panel opening. Slide strain relief nut onto work cable and secure strain relief to front panel.

9Work Lead Ring Terminal And WORK BLACK Terminal

Connect ring terminal on end of work clamp lead to terminal labeled WORK BLACK. Route lead along torch lead bundle.

Reinstall wrapper.

Ref. 804 887-A / 244 409-A / Ref. 244 405-A

OM-244 013 Page 29