4-1. Specifications
Power Supply
Input
Rated AC phase (PH) and line frequency (Hz) | 1 PH |
| 60 Hz |
| — — | ||
|
|
|
|
|
| ||
Rated Input Voltage (U1) and rated Input | Volts AC RMS | (U1) | Amps RMS | (I1) | I1 eff | ||
Current (I1) and I1 eff at rated output. I1 eff used | 208 Volts |
| 33 |
| 23.3 | ||
to determine power cord rating |
|
|
|
|
|
| |
230 Volts |
| 30 |
| 21.2 | |||
|
|
| |||||
|
|
|
|
| |||
| Volts AC RMS | (U1) | Power Factor | KVA/KW | |||
Power Factor/KVA/KW at Rated Output | 208 Volts |
| 0.98 |
| 6.8/6.6 | ||
|
|
|
|
|
| ||
| 230 Volts |
| 0.98 |
| 6.8/6.6 | ||
|
|
|
|
|
| ||
Peak KW at Arc Stretch | 10.1 KW |
| — — |
| — — | ||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Output |
|
|
|
|
|
| |
|
|
|
|
| |||
Rated Open Circuit Voltage (U0) Type | 400 Volts DC/Electrode Negative | — — |
| — — | |||
|
|
|
|
| |||
Output Characteristic | Constant Current | — — |
| — — | |||
|
|
|
|
|
| ||
Output Current Range |
| — — |
| — — | |||
|
|
|
|
|
| ||
| Amps DC | (I2) | Volts DC | (U2) | Volts AC | ||
Output Current and Voltage Rating at Rated | RMS | (U1) | |||||
|
|
|
| ||||
Input Voltage (I2 and U2 at U1) | 40 A |
| 140 Volts DC | 208 Volts | |||
| 40 A |
| 140 Volts DC | 230 Volts | |||
|
|
|
|
|
| ||
| Duty Cycle % | Amps DC | (I2) | Volts AC | |||
Duty Cycle at 1045 F (405 C) at rated conditions | RMS | (U1) | |||||
|
|
|
| ||||
(U1, I1, U2, I2) based on a 10 minute period | 50 |
| 40 A |
| 208 Volts | ||
| 50 |
| 40 A |
| 230 Volts | ||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
General |
|
|
|
|
|
| |
|
|
|
|
| |||
Operating Temperature | 5° to 104° F ( 15° to 40° C) | — — |
| — — | |||
|
|
|
|
|
| ||
| IP23CS |
| — — |
| — — | ||
|
|
|
|
| |||
| IP International Protection | — — |
| — — | |||
|
|
|
|
|
| ||
| 2 No ingress of foreign objects 12.5 mm | — — |
| — — | |||
IP Code Degree of protection provided by | (0.5 in.) |
|
| ||||
|
|
|
|
| |||
enclosure |
|
|
|
|
|
| |
3 No harmful ingress spraying water | — — |
| — — | ||||
|
| ||||||
|
|
|
|
|
| ||
| C AC line circuits protected against ingress of | — — |
| — — | |||
| tool ≥ 2.5 mm dia x 100 mm long (0.1 in. x 4 in.) |
| |||||
|
|
|
|
| |||
|
|
|
|
| |||
| S Fan stationary during water test | — — |
| — — | |||
|
|
|
|
| |||
Toppling or tilting | Up to 15° incline | — — |
| — — | |||
|
|
|
|
| |||
Gas Type | Air or Nitrogen | — — |
| — — | |||
|
|
|
|
| |||
Gas Quality | Clean, | — — |
| — — | |||
|
|
|
|
| |||
Gas Inlet Flow and Pressure | 4.8 SCFM (85 L/min) | 90 PSI (621 kPa) | 120 PSI (827 | ||||
Min |
| kPa) Max | |||||
|
|
|
| ||||
|
|
|
|
| |||
Gas Filtering | Particulates to 5 microns | — — |
| — — | |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Torch |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Mild Steel capacities (see Section | — — |
| — — |
| — — | ||
cutting speeds vs material type and thickness) |
|
| |||||
|
|
|
|
|
| ||
|
|
|
|
| |||
Rated Capacity (edge start) | 5/8 in. at 9 ipm (229 mm/min)* | — — |
| — — | |||
|
|
|
|
| |||
Sever Cut Capacity (edge start) | 7/8 in. (22 mm) | — — |
| — — | |||
|
|
|
|
| |||
Pierce Capacity | 5/16 in. (8 mm) | — — |
| — — | |||
|
|
|
|
|
|
| |
*Travel speeds are approximately 80% of maximum. |
|
|
|
|
|
|