2-12. Electrical Service Guide

Input Voltage

200

230

460

575

 

 

 

 

 

Input Amperes At Rated Output

50

44

22

17

 

 

 

 

 

Max Recommended Standard Fuse Or Circuit Breaker Rating In

80

70

35

25

Amperes

 

 

 

 

 

 

 

 

 

Min Input Conductor Size In AWG/Kcmil

8

8

10

12

 

 

 

 

 

Max Recommended Input Conductor Length In Feet (Meters)

93 (28)

124 (38)

329 (100)

313 (95)

 

 

 

 

 

Min Grounding Conductor Size In AWG/Kcmil

8

8

10

12

 

 

 

 

 

Reference: 1996 National Electrical Code (NEC)

 

 

 

S-0092J

 

 

 

 

 

2-13. Selecting A Location And Connecting Input Power

Have only qualified persons make this installation.

1 Rating Label

Supply correct input power.

Y Special installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC Section 20.

18 in (457 mm) for airflow

GND/PE

Connect First L1

1

GND/PE

L2

Size and ratings must comply with ap- plicable codes. Install conductors in conduit or equivalent into a deener- gized line disconnect device (see Section 2-12).