3-7. Volt-Ampere Curves

DC Volts

A. CC/DC (Standard)

100

 

 

Ranges: 190–Max

80

110–270

85–210

 

 

55–110

 

Min–65

60

 

40

20

0

0

100

200

300

400

500

600

700

The volt-ampere curve shows the minimum and maximum voltage and amperage output capabilities of the welding generator. Curves of all other settings fall between the curves shown.

DC Amperes

AC Volts

B. CC/AC (Models with Optional Polarity/AC Selector Switch)

100

80

60

40

20

0

0

100

200

300

400

500

600

700

AC Amperes

C. CV/DC (Models with Optional CV-3 Module)

rsb13.1 12/94 – ST-184 477-A / ST-184 475-A / ST-184 480-A

OM-474 Page 13

Page 17
Image 17
Hobart Welding Products OM-474 manual Volt-Ampere Curves, DC Volts CC/DC Standard, Ranges 190-Max 110-270, Min-65