Section 3: Operation

Controls and Indicators

Button and indicator locations on the Dripmaster control panel are shown below.

Presence of oil

2

Dripmaster window

area

 

 

Lack of oil 1

Display switch 17

Freeze 16

12-second timer 15

Drip rate display 14

Timing toggle 13 switches

3Pre-lube (pump off) mode

4Drip rate

5 Valve opening

6

Open Valve

7

Valve fully open

8Control Mode

9 Manual Operation

10 Close Valve

11Valve Closing

12Drip Rate toggle switches

Figure 6: Dripmaster control panel

Table 3: Control panel—controls and indicators

Item

Name

Control or

number

 

Indicator

(Figure 6)

 

 

1

Oil

Red LED

 

 

 

Function

Lights if the valve is completely closed, indicating a complete absence of oil.

A corresponding relay contact closes when this LED is on. The terminal for this contact is called LL (Lower Limit) and appears in Figure 5 on page 10.

13

Page 13
Image 13
Hoffman Media EDD-4C manual Operation, Controls and Indicators