Advanced Menu
To adjust the source gain and the connection status of each source, whether IR is enabled or disabled, whether IR is passed to the audio sources, zone groups, and paging volume, press and hold the knob on the VSC for more than 5 seconds to enter the Advanced Menu. Release the knob when the display shows "G1".
In the Advanced Menu, you can cycle between each item by pressing the knob. Each time the button is pressed, the next item is displayed. Advanced Menu items are circular; thus, when you are on the last menu item (i.e. Paging Volume) you will switch back to the first menu item (i.e. Source 1 Gain) by pressing the knob once again. When the item that you want to adjust is displayed, it may be modify by turning the knob clockwise or counterclockwise.
It should be noted that only one VSC can access the advanced menu at a time. If a second VSC tries to access the advanced menu, the second VSC will be denied access to the advanced menu.
Display | System Setting | Default Value | Range |
|
|
|
|
G1 | Source 1 (Gain / Connected) | 0 | 0 to 15 / FF for disconnected |
G2 | Source 2 (Gain / Connected) | 0 | 0 to 15 / FF for disconnected |
G3 | Source 3 (Gain / Connected) | 0 | 0 to 15 / FF for disconnected |
G4 | Source 4 (Gain / Connected) | 0 | 0 to 15 / FF for disconnected |
G5 | Source 5 (Gain / Connected) | 0 | 0 to 15 / FF for disconnected |
G6 | Source 6 (Gain / Connected) | 0 | 0 to 15 / FF for disconnected |
Gr | Zone Group | Off | On / Off (FF) |
Ir | IR On / Off | On | On / Off (FF) |
IP | IR Passthrough | On | On / Off (FF) |
PG | Page Volume | 0 | 0 to 99 |
If there is no interaction with the VSC for more than 20 seconds, the menu will be exited and the display will revert back to the volume setting. You can also manually exit from the Advanced Menu by pressing and holding the knob for at least 2 seconds.
Page 5