OPERATION
PLUG
Most motorized appliances
require more than theirrated
wattage for startup.
Plug in the appliance.
Determine if the cause is a shortcircuit in a connected appliance, an
overload, or an overheated inverter.Correct the problem and restart
the generator.
Before connecting an appliance to the generator, makesure that it is in
good order and that its electricalrating does not exceed that of the
generator. Then startthe generator and connect the appliance power
cord.
If the generator is overloaded, or if there is a short circuit in a
connected appliance, or if the inverter is overheated, the overload
indicator (red) will come ON. The overload indicator (red) will stay ON,
and after about five seconds, current to the connected appliance(s) will
shut off, and the output indicator (green) will go OFF. Stop the engine
and investigate the problem.
When an electric motor is started,the overload indicator (red) may
come on. This is normalif the overload indicator (red) goes off after
about five seconds. If the overload indicator (red) stays on, consult an
authorized Honda generator dealer.