OPERATION
AC Receptacle Selection
The generator has separate main powerproducing circuits. These two
circuits supply power to different receptacles shown when the voltage
selector switch is in the 120/240 V position.
When two or more receptacles areused, prevent overloading by
dividing the load between the two power circuits.
The chart below shows the ratedload in amperes that can be
connected to each receptacle to balance the generator when the 120/
240 V locking plug receptacle is used for 120 V.
The total rated amperedraw is:
Receptacles powered
by each main circuit
1, 3 and 4
2and5
Power distribution
1 3 4=18.8A rated.
2 5=18.8A rated.
Receptacles powered
by each main circuit
1, 3 and 4
2and5
Power distribution
1 3 4=22.9A rated.
2 5=22.9A rated.
Main power circuit
Main Circuit I
Main Circuit II
Main power circuit
Main Circuit I
Main Circuit II
37.5 A
45.8 A
EM5000is
EM7000is
EM5000is:
EM7000is: