19
CONTROL & FEATURES
i-Monitor
i-Monitor at Start Up
i-Monitor DisplayMode 1 Total OperatingHours
i-Monitor Display
Display Backlight Flashes
i-MONITOR BUTTON
SINGLE-DIGIT
SCREENDISPLAY
FOUR-DIGIT
SCREENDISPLAY
TM
TM
TM
TM
TM
TM
TM
TM
TM
TM
TM
The i-Monitor isa user interface that allows the operator to view
(when the generator is running) total operatingtime in hours,
generator output, engine RPM,battery voltage and error messages.
The different display modes are selected by pressing the i-Monitor
button.
This mode displays the total operating hours of the generator.When
the generator is running, the total operating time accumulates. If the
total operating time is less than one hour, thenumeric display will be
‘‘0.’’ When the operating time is one hour orgreater, the display will
be ‘‘1’’ or ‘‘2’’ and so on. Base the generator’smaintenance schedule
on the accumulated time displayed.
The i-Monitor displayis divided into two screens. The single-digit
screen displays the i-Monitor modewhich is represented by a
number 1 through 4.The f our-digitscreen displays the four mode
values or any activated error messages.
During start up, the i-Monitor displayand all three indicators will
simultaneously blink once. The condition of the i-Monitor display
andallthreeindicatorscanbecheckedwiththeaidofanobserver.
Once the generator is running, the Outputindicator (green) and the
i-Monitor display will remain lit.
If the key is left in the ON position for over 30 seconds without starting
the engine, the display will startto f lash.
TM
05/04/25 09:40:57 31Z11600_020