31
OPERATION
OVERLOADINDICATOR
Plug in the appliance following the instruction provided with the
parallel operation cable kit.
Turn on the appliance.
If the generators are overloaded (see page ), or if there is a short
circuit in a connected appliance, the overload indicator (red) will go
ON. The overload indicator (red) will stay ON, and after about four
seconds, current to the connected appliance(s) will shut off, and the
output indicator (green) will go OFF. Stop both eng ines and
investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an
overload. Correctthe problem and restart the generator.
3.
4.
33