34
OPERATION
REDLEAD
BLACKLEAD
BATTERYCHARGING CABLE
(optionalequipment)
Connect the red lead of the battery charging cable to thepositive
( ) battery terminaland the black lead to the negative ( ) battery
terminal.
Plug the battery charging cable into the DCreceptacle of the
generator.
Start the generator.
Do not start the vehicle while the battery chargingcable is connectedand the generator is running. The vehicle orthe generator may bedamaged.
An overloaded DC circuit, excessive currentdrawn by the battery, or a
wiring problem willtrip the DC circuit protector (the yellow indicator
inside the clear circuit protector button willpop out). If this happens,
wait a few minutes before pushing in the circuit protector button to
resume operation. If the circuit protector continues to go OFF,
discontinue charging and see your authorizedHonda generator dealer.
The DC circuit protector does not prevent overcharging the battery.
2.
3.
4.
09/12/15 10:08:28 31ZT7620_035