Important! The following cleaning solutions have been tested to assure safe cleaning of your scanner’s disinfectant-ready housing. They are the only solutions approved for use with these scanners. Damage caused by the use of cleaners other than those listed below may not be covered by the warranty.

Sani-Cloth®HB wipes

Sani-Cloth®Plus wipes

Super Sani-Cloth®wipes

Isopropyl Alcohol wipes (70%)

CaviWipes

Virex® 256

409® Glass and Surface Cleaner

Windex® Blue

Clorox® Bleach – 10%

Gentle dish soap and water

Inspecting Cords and Connectors

Inspect the interface cable and connector for wear or other signs of dam- age. A badly worn cable or damaged connector may interfere with scanner operation. Contact your distributor for information about cable replace- ment. Cable replacement instructions are on page 11-2.

Replacing Cables in Corded Scanners

The standard interface cable is attached to the scanner with an 10-pin modular connector. When properly seated, the connector is held in the scanner’s handle by a flexible retention tab. The interface cable is designed to be field replace- able.

Order replacement cables from Honeywell or from an authorized distributor.

When ordering a replacement cable, specify the cable part number of the original interface cable.