MSI

<Default All MSI Settings>

MSI

On

* Off

MSI Check Character

Different types of check characters are used with MSI bar codes. You can program the image scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit.

When Check Character is set to Validate Type 10 and Transmit, the image scanner will only read MSI bar codes printed with the specified type check character, and will transmit this character at the end of the scanned data.

When Check Character is set to Validate Type 10, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character, but will not transmit the check character with the scanned data.

*Validate Type 10, but Don’t Transmit

Validate Type 10 and Transmit

7 - 28