Honeywell CT3650 manual Wire Wallplate Terminals

Models: CT3650

1 24
Download 24 pages 31.94 Kb
Page 8
Image 8
STEP 4. WIRE WALLPLATE TERMINALS

STEP 4. WIRE WALLPLATE TERMINALS

IMPORTANT

All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heat- ing/air-conditioning contractor.

Refer to the labels you placed on the wires when you removed the old thermostat (see illustration).

Match the letter of your old thermostat wire with the corresponding terminal letter on your new thermostat. Refer to Table 2.

Remove the factory-installed jumper connecting terminals R and RC if wires are connected to both of those terminals.

For wiring diagrams, if needed, see pp 21-22.

Loosen the terminal screws. Slip each wire beneath its matching terminal. Wraparound and straight connections are both acceptable, (see illustration). Tighten the terminals.

FOR WRAPAROUND

FOR STRAIGHT INSERTION

INSERTION STRIP

STRIP 5/16 IN. (8 MM).

7/16 IN. (11 MM).

 

 

M4826

R

W

Y

Manual backgroundManual backgroundG

M16425

Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation.

69-1285—2

8

Page 8
Image 8
Honeywell CT3650 manual Wire Wallplate Terminals