STEP 3. MOUNT THERMOSTAT WALLPLATE
❑Separate the wallplate from the thermostat by placing your thumb or fingers
between the bottom of the wallplate and the thermostat, and pulling the wallplate up and away from the thermostat. See illustration at right.
❑Position the wallplate on the wall. Level the wallplate for appearance if desired.
Use a pencil to mark the two mounting holes that best fit the application.
❑Remove the wallplate from the wall. Drill two 3/16 in. holes in wall (if drywall) as
| shown. For materials such as plaster or wood, drill 7/32 in. holes where marked. |
|
| Gently, tap the (provided) anchors into the drilled holes until they are flush with |
|
| the wall. |
|
❑ | Reposition the wallplate over the holes. Pull the wires through the wiring | M16427 |
|
opening. Loosely insert mounting screws into each of the holes.
❑Level the wallplate if desired. Thermostat functions properly when not level.
❑Tighten mounting screws.
WALL
WIRES
THROUGH WALL
WALL
ANCHORS (2)
MOUNTING
HOLES
MOUNTING
SCREWS
M15044