2.2 SUPPLIED CABLES

2.2.1Eight-Way RJ45 Connector to Eight-Way RJ45 Connector

This cable is used to connect a slave keyboard to a master keyboard, a slave keyboard to a slave keyboard, and a master keyboard to a multiplexer.

2.2.2Eight-Way RJ45 Connector to White/Orange Wire and Orange Wire

This cable is used to connect the master keyboard to the domes RS485 connection. The orange/white wire is data +, and the orange wire is data -.

2.2.3Eight-Way RJ45 Connector to Green Wire and Blue Wire

This cable is used to connect the master keyboard to the DVRs RS485 connection. The green wire is data +, and the blue wire is data -.

This cable can also be used to input Orbiter / RapidDome RS485 data from a control device to the master keyboard, or last slave keyboard. Again the green wire is data +, and the blue wire is data -.