System Setup

If the buzzer is enabled (see Setting the Internal Alarm Buzzer, page 20), the

HRTL-One also buzzes to alert the user.

No = The alarm is not turned on. The system will not respond when it detects an alarm condition.

Press Menu to confirm your changes.

3.Press S or T to select the Alarm Duration field, then press Enter.

Press S or T to choose from the following options:

10 Sec, 15 Sec, 20 Sec, 30 Sec, 1 Min, 2 Min, 3 Min, 5 Min, 10 Min, 15 Min, 30 Min,

Always = Until the alarm condition is reset (pin 13 of the COM port)

Press Menu to confirm your changes.

4.Press S or T to select the Record IPS (images per second) field, then press Enter.

Press S or T to choose from the following options:

NTSC = 1, 2, 4, 8, 15, 30, 60

OR

PAL = 1, 2, 3, 6, 12, 25, 50

Press Menu to confirm your changes.

5.Press S or T to select the Record Quality field, then press Enter. Press S or T to choose from the following options:

Best, High, Normal, Basic Press Menu to confirm your changes.

6.Press S or T to select the Record Mode field, then press Enter. Press S or T to choose from the following options:

Fields, Frames

Press Menu to confirm your changes.

7.Press Menu to exit this screen and confirm the current operations.

8.If you have completed all your system configuration changes, press Menu again to exit and close menu setup.

Rev 1.00

28

Document 900.0259

 

 

10/04