Honeywell VISTA-128FB manual Programming Device Timers cont’d, DAYS? Mtwtfss HIT 0-7 X Permanent ?

Models: VISTA-32FB VISTA-128FB

1 72
Download 72 pages 22.25 Kb
Page 47
Image 47

Programming Device Timers (cont’d)

00 ON TIME ? 00:00 PM

00 OFF TIME ? 00:00 PM

00 DAYS? MTWTFSS HIT 0-7 X X

00 PERMANENT ?

0 = NO, 1 = YES 0

Enter the time you want the device turned on using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication.

Enter 00:00 if this timer is not being used to turn something ON for the days selected below. (ex. using one timer to turn lights on one day and using another timer to turn them off on another day).

Enter the time you want the device turned off using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication.

Enter 00:00 if this timer is not being used to turn something OFF for the days selected below. (ex. using one timer to turn lights on one day and using another timer to turn them off on another day).

Select the days on which the device is to be activated by entering 1-7 (Monday = 1). An "X" will appear under that day, indicating the output for that day is active. Entering a day’s number again will deactivate that day. Pressing 0 will turn all days on/off. The outputs will only be in effect for the days that have the letter x underneath them. As the week progresses, the days are reset to the inactive state, unless the permanent option is selected (next screen prompt). When completed, press * to continue.

Answering 1 (YES) means the system executes this timer continuously. Answering 0 (NO)means the system executes each day’s output only once.

– 47 –

Page 47
Image 47
Honeywell VISTA-128FB, VISTA-32FB manual Programming Device Timers cont’d, DAYS? Mtwtfss HIT 0-7 X Permanent ?