SUMMARY OF AUDIBLE/VISUAL NOTIFICATION

~

SOUND

LOUD, INTERRUPTED*

Console & External

LOUD, CONTINUOUS”

Console & External

ONE SHORT BEEP (not repeated) Console only

ONE SHORT BEEP (once every 60 seconds) Console only

ONE BEEP every 60 sec. Console only

TWO SHORT BEEPS Console only

THREE SHORT BEEPS Console only

RAPID BEEPING

Console only

SLOW BEEPING

Console only

CAUSE

FIRE AURM

BURGLARY/AUDIBLE

EMERGENCY ALARM

a. SYSTEM DISARM

b. SYSTEM ARMING AITEMPT WITH AN OPEN ZONE

c. BYPASS VERIFY

SYSTEM IS IN TEST MODE

a. LOW BAITERY AT XfvfTR b. SYST. MAIN BAIT. WEAK c. TROUBLE

ARM AWAY OR MAXIMUM

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYS-

TEM IS IN CHIME MODE

c. ZONE OPENED WHILE SYS-

TEM IS IN TEST MODE MEMORY OF ALARM

a. ENTRY DELAY WARNING

b. EXIT DELAY ALERT (if programmed)

DISPLAY

FIRE and flLflRM are displayed; protection zone in alarm is displayed.

flL13RM is displayed; protection zone in alarm is also displayed. Also see ‘Exit Alarm Warning Displays and Sounds” on page 21.

a. Only RERDY is displayed. Green READY indicator (if present) is lit. b. NOT REFIDV is displayed, open protection zone number is displayed.

Green READY indicator (if present) is not lit.

c. The bypassed protection zone numbers are displayed. (One beep for each number displayed.) BYP13SSdisplayed.

Opened Zone identifications will appear.

a.BAT displayad with ID number of transmitter.

b.BAT displayed with no transmitter ID

c.CHECK displayed. Troubled protection zone is displayed, fitlJFIV and (if MAXIMUM) IN STFINTare displayad.

aST1l’f and (if INSTANT) 1NSTfiNT are displayed. Red ARMED indicatoris lit. b. CHIME displayed. Pressing W READY key will display opened zone.

C, open protectionzonenumber is displayed.

FIRE and/or llLft RM is displayed; zone in alarm is displayed,

a. No display during dela~ Exceeding the delay time without disarming causes alarm.

b. fifllll~ or (if MAXIMUM) FIUIFIY I NSTftNT is displayed. Slow beeps change to fast during last 5 sec of exit delay,

‘If bell is used as externalsounder,fire alarm is pulsedring;burglary/audibleemergencyis steady ring.

Note: Also see Power Failure, and Other Displays under TROUBLE CONDITIONS on page 27.