Hoshizaki 73183 service manual C. Display Module, Display Module Layout Display Module

Models: 73183

1 42
Download 42 pages 21.76 Kb
Page 16
Image 16
C. Display Module

C. Display Module

When the power switch is moved to the "ON" position there is a slight delay, then the current cabinet temperature is displayed. From the display module, the cabinet setpoint and temperature display scale can be changed. For further details, see "II.C.2. Controls and Adjustments."

Note: When power is turned on, the 2-hour high-temperature alarm timer is bypassed. Therefore, a high-temperature alarm can occur at startup. To silence the alarm, press and release the upper button. Alarm clears once temperature is within factory parameters. For details, see "II.D.2. Alarm Safeties."

1. Display Module Layout

Display Module

To Control Module

Display Cable

1. Display Module Layout Upper and Lower

Buttons

LED Display

Fig. 1

16

Page 16
Image 16
Hoshizaki 73183 service manual C. Display Module, Display Module Layout Display Module