E. Compressor Overload, Short Cycle Protection, and
1. Compressor External or Internal Overload
If combined temperature/amperage value is above the limit specified by the compressor manufacturer, the compressor overload operates independently to turn off the compressor. The compressor overload
•If the condenser fan motor is operating and the compressor is off, it is most likely that the compressor overload opened. If both the compressor and condenser fan motor are off, it is most likely the unit is off or the
•On refrigerators, the compressor overload is integrated with the start relay. On
2.Short-Cycle Protection
There is a
Note: Time may vary with compressor overload or
3. High-Pressure Switch
If pressure on the
high‑pressure switch activates and interrupts the compressor circuit, de‑energizing the compressor until the pressure returns to an acceptable level.
F. Mullion/Perimeter Heater
Refrigerators and freezers with mullions are equipped with mullion heaters. Freezers are also equipped with perimeter heaters. The heaters are energized as soon as the power switch is turned on.
G. Thermistors
The cabinet thermistor is used for cabinet temperature control and the defrost thermistor is used for defrost cycle initiation and termination. Thermistor resistance varies depending on temperature. The control module monitors the resistance to control system operation. No adjustment is required. For further details, see "IV.C. Thermistor Check."
20