Hoshizaki AM-150BWF Open the Shut-off Valve, Move the Control Switch to the “WASH” position

Models: AM-150BAF AM-150BWF AM-100BAE

1 21
Download 21 pages 11.05 Kb
Page 16
Image 16

8)Remove the Water Tank to drain the cleaning solution. Refit the Water Tank in its correct position.

9)Open the Shut-off Valve.

10)Move the Control Switch to the “WASH” position to circulate clean water for about 5 minutes.

11)Move the Control Switch to the “OFF” position and immediately back to the “WASH” position to rinse water.

12)Repeat the above rinse procedure three more times to rinse thoroughly.

13)Dilute approximately 0.5 fl. oz. (14.8 ml) of 5.25% Sodium Hypochlorite (Chlorine Bleach) with 1 gal. (3.8 lit.) of water.

14)Move the Control Switch to the “OFF” position. Close the Water Supply Line Shut-off Valve.

15)Remove the Water Tank to drain the water. Refit the Water Tank in its correct position.

16)Slowly pour the sanitizing solution into the Water Tank.

17)Move the Control Switch to the “WASH” position.

18)After circulating the sanitizing solution for about 15 minutes, move the Control Switch to the “OFF” position.

19)Remove the Water Tank to drain the sanitizing solution. Refit the Water Tank in its correct position.

20)Open the Shut-off Valve.

21)Move the Control Switch to the “WASH” position to circulate clean water for about 5 minutes.

22)Move the Control Switch to the “OFF” position and immediately back to the “WASH” position to rinse water.

23)Repeat the above rinse procedure two more times to rinse thoroughly.

24)Move the Control Switch to the “ICE” position, and start the automatic icemaking process. Refit the Front Panel (Lower) in its correct position.

13

Page 16
Image 16
Hoshizaki AM-150BWF, AM-100BAE, AM-150BAF Open the Shut-off Valve, Slowly pour the sanitizing solution into the Water Tank