2. LOCATION
WARNING
This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 50°F (10°C) to 100°F (38°C); Normal operating water temperature should be within 41°F (5°C) to 90°F (32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
For best operating results:
*The icemaker should not be located next to ovens, grills or other high heat producing equipment.
*The location should provide a firm foundation for the equipment. Level the icemaker from side to side and front to rear.
*Avoid a site where dripping is not allowed.
*This icemaker will not work at subfreezing temperatures. To prevent damage to the water supply line, drain the icemaker when air temperature is below zero.
*The
*The
5