2. LOCATION

2. LOCATION

WARNING

This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 50°F (10°C) to 100°F (38°C); Normal operating water temperature should be within 41°F (5°C) to 90°F (32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.

For best operating results:

*The icemaker should not be located next to ovens, grills or other high heat producing equipment.

*The location should provide a firm foundation for the equipment. Level the icemaker from side to side and front to rear.

*Avoid a site where dripping is not allowed.

*This icemaker will not work at subfreezing temperatures. To prevent damage to the water supply line, drain the icemaker when air temperature is below zero.

*The AM-100BAE icemaker requires no clearance at either side. But allow enough space at rear for water supply and drain connections, at least 12” (approx. 30 cm) clearance at front, and at least 0.6” (approx. 15 mm) clearance at top for maintenance.

*The AM-150BAF icemaker requires 2” (approx. 5 cm) clearance at either side. Allow enough space at rear for water supply and drain connections, at least 12” (approx. 30 cm) clearance at front, and at least 0.6” (approx. 15 mm) clearance at top for maintenance.