E. Diagnostic Tables
1. No Ice Production
No Ice Production - Possible Cause
1. Power Supply | a) Unplugged, off, blown fuse, or tripped breaker. | |
|
| |
| b) Not within specifications. | |
|
| |
2. Water Supply | a) Water supply off or improper water pressure. | |
| b) External water filters clogged. | |
|
| |
3. Optional Drain Pump | a) Safety switch open. | |
| ||
b) Connector loose or disconnected. | ||
| ||
|
| |
| c) Clogged or kinked hose. | |
| d) Defective. | |
4. Control Switch | a) In "OFF" or "WASH" position. | |
|
| |
| b) Bad contacts. | |
|
| |
5. Thermostatic Bin Control | a) Out of adjustment. | |
See "II.C. Bin Control Check" |
| |
b) Open with bin filled with ice. | ||
| ||
| c) Ambient temperature too cool. | |
|
| |
| d) Bulb out of position. | |
|
| |
| e) Bin control heater defective. | |
|
| |
| f) Defective. | |
6. Control Transformer | a) Defective. | |
(115VAC/24VAC) |
| |
(Auxiliary Code |
| |
|
| |
7. Control Board | a) Defective. | |
|
| |
8. Compressor | a) External protector defective. | |
|
| |
| b) PTC defective. | |
| c) Inefficient. | |
|
| |
| d) Open windings. | |
|
| |
9. Inlet Water Valve | a) Screen or orifice clogged. | |
|
| |
| b) Coil winding open. | |
| c) Inlet water valve remains open longer than 52 sec. in initial freeze | |
| cycle or remains open in normal freeze cycle. | |
|
| |
10. Hot Gas Valve | a) Closed in harvest cycle. | |
|
| |
| b) Open in freeze cycle. | |
|
| |
11. Inlet Water Valve | a) Screen or orifice clogged. | |
| b) Coil winding open. | |
|
| |
| c) Water valve open in freeze cycle. | |
|
| |
12. Hot Gas Valve | a) Closed in harvest cycle. | |
|
| |
| b) Open in freeze cycle. | |
13. Thermistor | a) Loose, disconnected, or defective. | |
See "II.E. Thermistor Check" |
| |
14. Pump Motor | a) Motor winding open. | |
|
| |
| b) Bearing worn out or locked rotor. | |
|
| |
| c) Defective capacitor. | |
|
| |
15. Fan Motor | a) Motor winding open. | |
| b) Bearing worn out or locked rotor. | |
|
|