V. Maintenance

V. Maintenance

This appliance must be maintained in accordance with the instruction manual and labels provided with the appliance. Consult with your local Hoshizaki Certified Service Representative about maintenance service.

A.Maintenance Schedule WARNING

Only qualified service technicians should service this appliance.

Failure to install, operate, and maintain the appliance in accordance with this manual will adversely affect safety, performance, component life, and warranty coverage.

Move the control switch to the "OFF" position and unplug the appliance from the electrical outlet before servicing.

To reduce the risk of electric shock, do not touch the control switch or plug with damp hands.

CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any maintenance is performed. Make sure that none have fallen into the ice storage bin.

After service, make sure that there are no wires pinched between the panels and appliance. Make sure you do not damage or pinch the water supply line, drain line, or power cord.

A.Maintenance Schedule

The maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the appliance's environment, and local sanitation regulations.

 

 

Maintenance Schedule

Frequency

Area

Task

 

 

 

Weekly

Scoop

Clean the scoop using a neutral cleaner. Rinse thoroughly after cleaning.

Monthly

External Water

Check for proper pressure and change if necessary.

 

Filters

 

 

Appliance Exterior

Wipe down with clean, soft cloth. Use a damp cloth containing a neutral

 

 

cleaner to wipe off oil or dirt build up. Clean any chlorine staining (rust

 

 

colored spots) using a non-abrasive cleaner like Zud or Bon Ami.

Every 3

Ice Storage Bin

Maintain as outlined in the instruction manual or maintenance label.

Months

Drain

 

Yearly

Appliance and Ice

Clean and sanitize per the cleaning and sanitizing instructions provided in

 

Storage Bin

the instruction manual.

 

Optional Drain

Test as outlined in "V.B. Optional Drain Pump HS-0248 or HS-5061."

 

Pump (HS-0248 or

 

 

HS-5061)

 

 

Water Supply Inlet

Close the icemaker water supply line shut‑off valve and drain the water

 

 

system. Clean the water supply inlet screen.

 

Condenser

Inspect. Clean if necessary.

 

Water Hoses

Inspect the water hoses and clean/replace if necessary.