6)A liquid charge is recommended when charging an
7)Allow the system to charge with liquid until the proper charge weight is met.
8)Close the
9)Cap the access valve to prevent a possible leak.
B.Component Service Information
NOTICE
When replacing a component listed below, see the notes to help ensure proper operation.
Component | Notes |
Compressor | Install a new drier and PTC relay. |
|
|
Hot Gas Valve | • Replace the strainer. |
| • Use copper tube of the same diameter and length when replacing valve lines. |
|
|
Pump Motor | Install a new capacitor. |
|
|
Thermistor | • Attach the new thermistor to the evaporator in the same location as the previous |
| thermistor. |
| • Smoothly fill the recessed area of the thermistor holder with high thermal conductive |
| type sealant. Hoshizaki America part number |
| |
| Silicones), or equivalent are recommended. |
| • Secure the thermistor with the holder. |
| • Be very careful to prevent damage to the leads. |
|
|
29