Hoshizaki DCM-500BWH-OS Control Board Layout a DCM-500BAH, DCM-500BWH, Part Number 2A1592-01

Models: DCM-500BWH-OS

1 69
Download 69 pages 57.62 Kb
Page 15
Image 15
1.Control Board Layout

1.Control Board Layout

a)DCM-500BAH, DCM-500BWH

Flush Switch

Must be left in the "P" position, otherwise the internal drain timer will not operate.

Counter Reset Button (not used in this application)

High

Pressure

Switch

Dispensing

Components

See "III.

B.Wiring Diagrams" for details.

Bin Control,

Control

Switch,

Low Water 10.5V

Safety Transformer

Portion Control

Microprocessor (board revision level

"POWER" LED

Timer

indicated by last 2 digits on label)

(lights when

 

"DM" LED

 

 

 

power is supplied

 

(X4 Relay)

 

to the board)

 

Shutter Solenoid,

"AM" LED

 

 

Dispensing Auger

(X3 Relay)

 

 

Motor

Agitating Motor

 

"COMP" LED

"GM" LED

(X2 Relay)

(X1 Relay)

Compressor,

Gear Motor

Fan Motor

 

"FLUSH" LED

 

(X5 Relay)

 

Drain Valve

 

24V Supply Out

 

Gear Motor

 

115V In

115V In

 

Protect Relay

115V In

Drain Valve 24V In

 

 

Circuit

 

24V Out

 

Gear Motor

Agitating Motor

 

Dispensing Motor

 

115V Out

115V Out

115V Out

 

 

 

Control Board

Part Number 2A1592-01

15

Page 15
Image 15
Hoshizaki DCM-500BWH-OS service manual Control Board Layout a DCM-500BAH, DCM-500BWH, Part Number 2A1592-01