13)Move the control switch to the "OFF" position, then turn off the power supply.

14)Close the water supply line shut-off valve.

c)Sanitizing Solution

Dilute 0.82 fl. oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with

1.6gal. (6.0 l) of warm water.

d)Sanitizing Procedure - Following Cleaning Procedure

1)Make sure the control switch is in the "OFF" position, the power supply is off, and the water supply line shutoff valve is closed.

2)Remove the front and top panels, then move the power switch to the "OFF" position.

3)Remove the front cover of the storage bin. Remove spout B, then remove spout A.

4)Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are full and the solution starts to overflow into the drain pan.

5)Replace spout A, spout B, and the front cover of the storage bin in their correct positions.

6)Allow the icemaker to sit for about 10 minutes before operation.

7)Move the power switch to the "ON" position and replace the panels in their correct positions. Turn on the power supply, then move the control switch to the "ICE" position. Make ice using the solution until the icemaker stops making ice.

8)Move the control switch to the "DRAIN" position and allow the solution to drain for

5 minutes.

9)Move the control switch to the "ICE" position. Open the water supply line shut-off valve to supply water to the reservoir.

10)After the gear motor starts, move the control switch to the "DRAIN" position and allow the water system to drain for 5 minutes.

11)Move the control switch to the "ICE" position to start the automatic icemaking process. Allow the icemaker to run for about 30 minutes, then clean and sanitize the dispensing components as outlined below.

2.Dispensing Components

Perform after cleaning and sanitizing the water system as outlined above.

a)Cleaning Solution

Dilute 9.6 fl. oz. (0.29 l) of recommended cleaner, Hoshizaki "Scale Away" or "LIME-A- WAY" (Economics Laboratory, Inc.), with 1.6 gal. (6.0 l) of warm water.

b)Sanitizing Solution

Dilute 0.82 fl. oz. (25 ml) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 1.6 gal. (6.0 l) of warm water.

c)Cleaning and Sanitizing Procedure

1)Move the control switch to the "OFF" position, then turn off the power supply.

2)Remove the front and top panels, then move the power switch to the "OFF" position.

65

Page 65
Image 65
Hoshizaki DCM-500BWH-OS c Sanitizing Solution, d Sanitizing Procedure - Following Cleaning Procedure, a Cleaning Solution