2. Features

2. Features

The control board provides the following safeguards:

Provides component protection during low water supply.

Purges remaining ice in the evaporator at startup and shutdown.

Provides short cycle protection for the compressor.

a)LED Lights

The "POWER" LED indicates control voltage and will remain on unless a control voltage problem occurs. An LED illuminates for each relay as it is energized. For more information, see "II.C. Sequence of Operation."

Icemaking

Cycle (Relay)

LED

Energized

 

Time LEDs are

Frequency LEDs are

Components

 

On

On

 

 

 

Fill

POWER only

WV

 

N/A

As Needed

Ice Purge (X1)

GM

GM

 

60 seconds

N/A

Freeze (X1, X2)

GM, COMP

GM, Comp,

 

N/A

N/A

FMS

 

 

 

 

 

 

Drain Valve (X6)

FLUSH

DV

 

20 Minutes

Every 12 Hours

 

 

 

 

 

 

 

Dispensing

 

 

Relay

LED

Energized

 

Time LEDs are

Frequency LEDs are

Component

 

On

On

 

 

 

 

Push Button

 

 

 

 

Ice Dispense (X4)

DM

IDM

 

60 seconds

N/A

Opti Serv

 

maximum

 

 

 

 

 

ICE

 

 

 

 

 

 

 

 

 

Every 12 seconds of

Agitating Motor (X3)

AM

AM

 

.6 seconds

accumulative dispense

 

 

 

 

 

time

Water Dispense (X5)

WTR

WTR

 

N/A

N/A

(Opti Serv Only)

 

 

 

 

 

Legend: AM–agitating motor, Comp–compressor; DV–drain valve; FMS–selfcontained fan motor; GM–gear motor; IDM–ice dispensing motor, shutter solenoid; WTR–dispensing water valve; WV–inlet water valve