Hoshizaki DCM-500BWH-OS service manual L. Removal and Replacement of Dispensing System

Models: DCM-500BWH-OS

1 69
Download 69 pages 57.62 Kb
Page 61
Image 61

10)Open the water supply line shut-off valve.

11)Turn on the power supply, move the power switch to the "ON" position, then replace the front panel in its correct position to engage the door switch. Move the control switch to the "ICE" position.

12)Allow the icemaker to fill for two minutes.

13)Move the control switch to the "OFF" position.

14)Remove the front panel and check for water leaks.

15)Move the control switch to the "DRAIN" position. Engage the door switch and make sure that water is draining and that there are no water leaks around the hose connection.

16)Move the control switch to the "OFF" position and disengage the door switch.

17)Replace the panels in their correct positions.

18)Move the control switch to the "ICE" position to start the automatic ice making process.

L. Removal and Replacement of Dispensing System

1.Dispensing Auger and Agitator

1)Move the control switch to the "OFF" position, then turn off the power supply. Remove the front and top panels, then move the power switch to the "OFF" position.

2)Remove the front cover of the storage bin.

3)Remove the thumbscrews from the vertical plane, then loosen the thumbscrews from the horizontal plane of the motor bracket. Slide the motor back.

Note: Hold the dispensing auger/agitator to prevent it from dropping when sliding back the motor. See Fig. 5.

4)Replace the dispensing auger/agitator with the new one.

5)Assemble the removed parts in the reverse order of which they were removed.

6)Move the power switch to the "ON" position, then replace the panels in their correct positions.

7)Turn on the power supply, then move the control switch to the "ICE" position to start the automatic icemaking process.

2.Dispensing or Agitating Motor

1)Move the control switch to the "OFF" position, then turn off the power supply. Remove the front and top panels, then move the power switch to the "OFF" position.

2)Remove the storage bin front panel.

3)Remove the thumbscrews from the vertical plane, then loosen the thumbscrews from the horizontal plane of the motor bracket. Slide the motor back.

Note: Hold the dispensing auger/agitator to prevent it from dropping when sliding back the motor. See Fig. 5.

4)Remove the thumbscrews from the horizontal plane of the motor bracket.

5)Remove the motor from the bracket.

61

Page 61
Image 61
Hoshizaki DCM-500BWH-OS service manual L. Removal and Replacement of Dispensing System, Dispensing Auger and Agitator